The DKG-116 is an inexpensive, comprehensive unit designed to start and stop a generator set both manually and remotely.
The unit is suitable for both gasoline and diesel generators. The standard unit controls gasoline engines. Diesel engine control is selected using a wire jumper.
The device is only available in a 12 V version.
Manual control is via the RUN and STOP buttons on the front panel. Remote control is via the REMOTE START input signal.
When the engine is running, the device monitors for faults and automatically shuts down the engine if an alarm occurs. Alarms are identified by a group of LEDs that display only the first one that occurs.
The device provides a set of digital program parameters. All parameters are changed using the buttons on the front panel.
FEATURES:• Manual and remote control• Generator protection• Built-in alarms and warnings• Remote start operation available• True RMS measurements• Tamper-proof hour display• Field adjustable parameters• High fuel and crank capacities• Auxiliary output• Auxiliary magnetic input• Digital inputs: 4• Withstands start-up tripping• Sealed front panel• Standard panel dimensions: 96×48 mm• Plug-in connection system
MEASUREMENT:⦁ Generator voltages: L1-N, L2-N, L3-N⦁ Generator voltages: L1-L2, L2-L3, L3-L1⦁ Generator frequency⦁ Battery voltage
OPTIONS:- Auxiliary output (negative pull).- Magnetic sensor input.
TECHNICAL SPECIFICATIONS: Generator voltage: 15 to 300 V-AC (Ph-N) Generator frequency: nominal 50 or 60 Hz. Measurement accuracy: 0.5% + 1 digit. Overspeed: nominal frequency + 14% (+24% overspeed) Low speed: 30 Hz. Cranking time: 10 sec. Crank rest: 10 sec. Cranking attempts: 3 Stop timer: 10 sec. Delay timer: 10 sec. DC power range: 9.0 to 16.0 V DC. Scrolling Cases: Withstands 0V for 100ms.Typical Standby Current: 12mA-DC (Display Off)Maximum Operating Current: 130mA DC Fuel and Crank Output: 10A @ 12V DC. Auxiliary Output: 1A @ 12V DC (Semiconductor Output with Negative Pull-up Protection) Magnetic Sensor Input: 1.5 to 30VppOperating Temperature: -40°C (-40°F) to 80°C (176°F). Maximum Humidity: 95% non-condensing. Dimensions: 102 x 55 x 40mm (W x H x D)Packaged Weight: 140gBody Material: High Temperature. ABS/PC (UL94-V0) IP protection: IP65 (front panel), IP30 (rear) Conformity (EU directives)-2006/95/EC (low voltage)-2004/108/EC (EMC) Reference standards:EN 61010 (safety requirements)EN 61326 (EMC requirements)