{"id":22568,"date":"2026-03-10T11:00:00","date_gmt":"2026-03-10T09:00:00","guid":{"rendered":"https:\/\/uhty.com.ua\/advert\/datakom-d-500-mk3-bagatofunktsionalnyj-kontroler-generatora-dvyguna-avr-z-mpu-j1939-2\/"},"modified":"2035-08-24T21:23:05","modified_gmt":"2035-08-24T18:23:05","slug":"datakom-d-500-mk3-bagatofunktsionalnyj-generatora-controller-dvyguna-avr-z-mpu-j1939-2","status":"publish","type":"advert","link":"https:\/\/uhty.com.ua\/en\/advertisement\/datakom-d-500-mk3-bagatofunktsionalnyj-generatora-controller-dvyguna-avr-z-mpu-j1939-2\/","title":{"rendered":"DATAKOM D-500-MK3 Multifunctional generator\/engine\/ATS controller with MPU + J1939"},"content":{"rendered":"<p>D-500-MK3 is a new generation generator set controller that combines multi-functionality and extensive communication capabilities with a robust and cost-effective design. The same controller provides synchronization, load sharing, AMF, ATS, remote start, engine control and remote display panel functions. The module is ready for remote monitoring via GSM or Ethernet using plug-in communication modules.<\/p>\n<p>Various plug-in modules provide unlimited expansion possibilities to meet any specific requirements. The device meets and mostly exceeds the most stringent global safety, vibration and environmental standards for the industrial category. Software features are complemented by a simple firmware update process via USB port. Windows-based PC software allows monitoring and programming via USB, RS-485, Ethernet and GPRS. Rainbow Scada web monitoring service allows monitoring and control of an unlimited number of generators via any web browser.<\/p>\n<p>FUNCTIONALITIES:- Multi-Generator Synchronizer and Load Sharing- Multi-Generator Grid Synchronizer- Single Generator Set Parallel to Grid- AMF Unit with Seamless Transfer- OPR Unit with Seamless Transfer- Remote Start Controller- Manual Start Controller- Engine Controller- Remote Display and Control Unit- V &amp; I Waveform Display- V &amp; I Harmonic Analysis<\/p>\n<p>COMMUNICATION:- Ethernet port (10\/100 Mb)- GSM-GPRS- Built-in web server- Web monitoring- Web programming- Central monitoring via the Internet- Sending SMS messages- Sending by e-mail- Central monitoring- Modbus RTU via RS-485- Modbus TCP\/IP- SNMP- USB host- CANBUS-2 for inter-module communication.- USB device- PC software: Rainbow Plus- J1939-CANBUS for electronic engines<\/p>\n<p>FEATURES:\u2022 Diesel and gas generator support\u2022 400 Hz operation support\u2022 400 event logs, full snapshot\u2022 All front panel parameters can be edited\u2022 3-level configuration password\u2022 128\u00d764 graphic LCD display\u2022 Downloadable languages\u2022 V &amp; I waveform display\u2022 V &amp; I harmonic analysis\u2022 Synchroscope and synchronization check\u2022 Allows closed transfers\u2022 16 A MCB and GCB outputs\u2022 8 configurable digital inputs\u2022 Inputs can be expanded to 40\u2022 8 configurable digital outputs\u2022 Outputs can be expanded to 40\u2022 7 configurable analog inputs\u2022 CANBUS-J1939 and MPU\u2022 3 configurable service alarms\u2022 Multiple topologies\u2022 6xCT, true network measurement\u2022 Supports up to 48 generators\u2022 Auto-learning\/self-tuning\u2022 Direct controller control and AVR\u2022 Voltage and phase matching\u2022 kW and kVA load sharing\u2022 True soft transfer in both directions\u2022 PLC functions\u2022 Peak Lopping\/peak shaving\u2022 Grid disconnection protection\u2022 ROCOF protection\u2022 Vector offset protection\u2022 Reverse power protection\u2022 Over\/under frequency. Protection\u2022 Surge Protection\u2022 Smart Load Management\u2022 Smart Genset Sequencing\u2022 Start\/Stop Priority Support\u2022 Equal Aging of Gensets\u2022 Base Load (Power Export)\u2022 Unmanaged Distributed Power Export Support\u2022 AVR and GOV Support\u2022 Faulty Bus Sensing\u2022 Multiple Auto Simulator\u2022 Weekly Schedule\u2022 Dual Mutual Redundancy with Equal Aging of Gensets\u2022 Manual \u00abFine Speed Control\u00bb on Selected ECUs\u2022 Automatic Fuel Pump Control\u2022 Disable Protection Function\u2022 Over Power Protection\u2022 Backfeed Protection\u2022 IDMT Overload Protection\u2022 Load Dump, Dummy Load\u2022 Multiple Load Management\u2022 Current Unbalance Protection\u2022 Voltage Unbalance Protection\u2022 Fuel Fill and Theft Alarm\u2022 Contactor and MCB Drive\u2022 Real Time Battery Clock\u2022 Idle Control\u2022 Battery Charging Enabled\u2022 Support combat mode\u2022 Multiple nominal conditions\u2022 4-quadrant genset power meters\u2022 Mains meters\u2022 Fuel fill meter\u2022 Fuel consumption meter\u2022 Modem and Ethernet diagnostics\u2022 Configurable via USB, RS-485, Ethernet and GPRS\u2022 Free configuration program\u2022 Allows SMS control\u2022 Ready for Ethernet and GPRS central monitoring\u2022 Mobile genset support\u2022 GSM automatic geolocation\u2022 GPS connectivity (USB and RS232)\u2022 Dynamic DNS support\u2022 Easy USB firmware upgrade\u2022 IP65 rated with standard gasket<\/p>\n<p>TECHNICAL SPECIFICATIONS: Generator voltage: 0 to 300 V-AC (Ph-N) Generator frequency: 0-600 Hz. Mains voltage: 0 to 300 V-AC (Ph-N) Mains frequency: 0-600 Hz. Topology: 1-2-3 phases, with or without neutral DC power supply range: 8.0 to 36.0 V DC. VA-cos Accuracy: 0.5% + 1 digit kW-kVA-kVAR Accuracy: 1.0% + 1 digit Current consumption: 500 mA-DC max. Current inputs: from current transformers. ..\/5A or ..\/1A.Digital inputs: input voltage from 0 to 36 VDC.Analog input range: 0-5000 Ohm.Mains and generator contactor outputs: 16 A at 250 VDC.DC outputs: protected MOSFET semiconductor outputs, rated voltage 1 A at 28 VDC.Scrolling cases: withstands 0 V for 100 ms.Magnetic sensor voltage: from 0.5 to 50 Vpc.Magnetic sensing frequency: from 0 to 20000 Hz.Charger generator excitation: 2 W.Screen: 2.9\u2033, 128\u00d764 pixels.Ethernet port: 10\/100 MbpsUSB device: USB 2.0 Full speedUSB host: USB 2.0 Full speedRS-485 port: baud rate selectable data rate (2400-115200 baud) RS-232 port: selectable data rate (2400-115200 baud) Operating temperature: -20\u00b0C to 70\u00b0C (-4 to +158\u00b0F) Storage temperature: -40\u00b0C to 80\u00b0C (-40 to +176\u00b0F) Maximum humidity: 95% non-condensing. IP protection: IP65 from front panel, IP30 from rear panel (with gasket) Dimensions: 211 x 162 x 42 mm (W x H x D) Panel cutout dimensions: minimum 176 x 121 mm. Weight: 500 g (approx.) Housing material: high-temperature, flame-retardant ABS\/PC Installation: flat surface mounting on type 1 housing. Rear plastic brackets are fixed.<\/p>\n<p>COMPLIANCE: Compliance with EU Directives -2014\/35\/EC (Low Voltage) -2014\/30\/EC (Electromagnetic Compatibility) Reference Standards: EN 61010 (Safety Requirements) EN 61326 (EMC Requirements) UL and CSA Compliance:\u2022 UL 6200, Controls for Stationary Motor Driven Units (File No. \u2013 20140725-E314374)\u2022 CAN\/CSA C22.2 No. 14-13 \u2013 Industrial Control Equipment<\/p>","protected":false},"excerpt":{"rendered":"<p>D-500-MK3 &#8211; \u0446\u0435 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0435\u0440 \u0433\u0435\u043d\u0435\u0440\u0430\u0442\u043e\u0440\u043d\u043e\u0457 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0438 \u043d\u043e\u0432\u043e\u0433\u043e \u043f\u043e\u043a\u043e\u043b\u0456\u043d\u043d\u044f, \u0449\u043e \u043f\u043e\u0454\u0434\u043d\u0443\u0454 \u0431\u0430\u0433\u0430\u0442\u043e\u0444\u0443\u043d\u043a\u0446\u0456\u043e\u043d\u0430\u043b\u044c\u043d\u0456\u0441\u0442\u044c \u0456 \u0448\u0438\u0440\u043e\u043a\u0456 \u043a\u043e\u043c\u0443\u043d\u0456\u043a\u0430\u0446\u0456\u0439\u043d\u0456 \u043c\u043e\u0436\u043b\u0438\u0432\u043e\u0441\u0442\u0456 \u0440\u0430\u0437\u043e\u043c \u0437 \u043d\u0430\u0434\u0456\u0439\u043d\u043e\u044e \u0442\u0430 \u043d\u0435\u0434\u043e\u0440\u043e\u0433\u043e\u044e \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0456\u0454\u044e. \u0422\u043e\u0439 \u0441\u0430\u043c\u0438\u0439 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0435\u0440 \u0437\u0430\u0431\u0435\u0437\u043f\u0435\u0447\u0443\u0454 \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0456\u0437\u0430\u0446\u0456\u044e, \u0440\u043e\u0437\u043f\u043e\u0434\u0456\u043b \u043d\u0430\u0432\u0430\u043d\u0442\u0430\u0436\u0435\u043d\u043d\u044f, \u0444\u0443\u043d\u043a\u0446\u0456\u0457 AMF, ATS, \u0434\u0438\u0441\u0442\u0430\u043d\u0446\u0456\u0439\u043d\u043e\u0433\u043e \u0437\u0430\u043f\u0443\u0441\u043a\u0443, \u043a\u0435\u0440\u0443\u0432\u0430\u043d\u043d\u044f \u0434\u0432\u0438\u0433\u0443\u043d\u043e\u043c \u0442\u0430 \u0432\u0456\u0434\u0434\u0430\u043b\u0435\u043d\u043e\u0457 \u043f\u0430\u043d\u0435\u043b\u0456 \u0434\u0438\u0441\u043f\u043b\u0435\u044f. \u041c\u043e\u0434\u0443\u043b\u044c \u0433\u043e\u0442\u043e\u0432\u0438\u0439 \u0434\u043e \u0432\u0456\u0434\u0434\u0430\u043b\u0435\u043d\u043e\u0433\u043e \u043c\u043e\u043d\u0456\u0442\u043e\u0440\u0438\u043d\u0433\u0443 \u0447\u0435\u0440\u0435\u0437 GSM \u0430\u0431\u043e Ethernet \u0437\u0430 \u0434\u043e\u043f\u043e\u043c\u043e\u0433\u043e\u044e \u0432\u0441\u0442\u0430\u0432\u043d\u0438\u0445 \u043a\u043e\u043c\u0443\u043d\u0456\u043a\u0430\u0446\u0456\u0439\u043d\u0438\u0445 \u043c\u043e\u0434\u0443\u043b\u0456\u0432. \u0420\u0456\u0437\u043d\u0456 \u043c\u043e\u0434\u0443\u043b\u0456&#8230;<\/p>","protected":false},"author":3167,"featured_media":22569,"comment_status":"open","ping_status":"closed","template":"","advert-category":[822,839],"advert-location":[2075],"class_list":["post-22568","advert","type-advert","status-publish","has-post-thumbnail","hentry","advert-category-biznes-ta-poslugy","advert-category-obladnannya","advert-location-rivne"],"_links":{"self":[{"href":"https:\/\/uhty.com.ua\/en\/wp-json\/wp\/v2\/advert\/22568","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/uhty.com.ua\/en\/wp-json\/wp\/v2\/advert"}],"about":[{"href":"https:\/\/uhty.com.ua\/en\/wp-json\/wp\/v2\/types\/advert"}],"author":[{"embeddable":true,"href":"https:\/\/uhty.com.ua\/en\/wp-json\/wp\/v2\/users\/3167"}],"replies":[{"embeddable":true,"href":"https:\/\/uhty.com.ua\/en\/wp-json\/wp\/v2\/comments?post=22568"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/uhty.com.ua\/en\/wp-json\/wp\/v2\/media\/22569"}],"wp:attachment":[{"href":"https:\/\/uhty.com.ua\/en\/wp-json\/wp\/v2\/media?parent=22568"}],"wp:term":[{"taxonomy":"advert-category","embeddable":true,"href":"https:\/\/uhty.com.ua\/en\/wp-json\/wp\/v2\/advert-category?post=22568"},{"taxonomy":"advert-location","embeddable":true,"href":"https:\/\/uhty.com.ua\/en\/wp-json\/wp\/v2\/advert-location?post=22568"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}